ASTM F1001 Chemical Test Battery*
Chemical Zytron® ChemTape®
100 100XP 200 300 400 500
Acetone NT NT 17 >480 >480 >480 >480
Acetonitrile NT NT 52 87 >480 >480 >480
Carbon Disulfide NT NT 2 >480 >480 >480 >480
Dichloromethane NT NT 2 70 88 >480 >480
Diethylamine NT NT 21 >480 >480 >480 160
Dimethylformamide NT NT 77 >480 >480 >480 >480
Ethyl Acetate NT NT 14 >480 >480 >480 >480
n-Hexane NT NT 7 >480 >480 >480 >480
Methyl Alcohol NT NT >480 55 >480 >480 >480
Nitrobenzene NT NT 97 >480 >480 >480 >480
Sodium Hydroxide >480 >480 >480 >480 >480 >480 >480
Sulfuric Acid >480 >480 >480 >480 >480 >480 >480
Tetrachloroethylene NT NT 21 >480 >480 >480 >480
Tetrahydrofuran NT NT 3 >480 >480 >480 >480
Toluene NT NT 6 >480 >480 >480 >480
*Normalized breakthrough times in minutes in accordance with ASTM F 739.
Gases
Gases Zytron® ChemTape®
100 100XP 200 300 400 500
Ammonia Gas NT NT NT 39 NT >480 NT
1,3 Butadiene NT NT NT >480 NT >480 NT
Chlorine Gas NT NT NT >480 NT >480 NT
Ethylene Oxide Gas NT NT NT 81 305 >480 NT
Hydrogen Chloride Gas NT NT NT >480 NT >480 NT
Methyl Chloride Gas NT NT NT >480 NT >480 NT
Chemical Warfare Agent Data
Chemical Agent Zytron® 300
Breakthrough Time Breakthrough Criteria
Agent testing was conducted at Battelle Labs in accordance with MIL-STD-282 and/or NFPA 1994-2001 Edition Standard on Protective Ensembles for Chemical / Biological Terrorism Incidents.
Bis (2-chloroethyl) sulfide (Mustard:HD) >480 MINUTES 4.0 ug/cm2
Isopropyl methylfluorophosphonate (Sarin:GB) >480 MINUTES 1.25 ug/cm2
Chlorovinyl arsinedichloride (Lewisite:L) >240 MINUTES 4.0 ug/cm2
0-ethyl S-(2-diisopropylaminoethyl) methylphosphonothiolate (Nerve:VX) >480 MINUTES 1.25 ug/cm2
Typical Physical Properties for Zytron
Test Method 100 100XP 200 300 400 500
Grab Tensile Strength MD* ASTM D751(lbs/N) 32 / 142 49 / 217 52 / 231 78 / 347 155 / 689 120 / 534
Grab Tensile Strength CD* ASTM D751(lbs/N) 24 / 106 38 / 169 39 / 173 69 / 307 152 / 676 121 / 538
Tear Resistance Trapezoid Method MD* ASTM D751(lbs/N) 11.5 / 51 17.4 / 77 22.9 / 101.8 16.6 / 74 42.2 / 188 35 / 156
Tear Resistance Trapezoid Method CD* ASTM D751(lbs/N) 7.4 / 32 10.3 / 45 9.6 / 42.7 22.1 / 98 50.6 / 225 37 / 168
Ball Burst ASTM D3787 (lbs/N) 28 / 124 46 / 204 43 / 191 583 / 258 153 / 681 128 / 569

* MD - Machine Direction | CD - Cross Direction

Need A Specific Chemical Tested?

Know before you buy with Kappler's free testing program.

If you need to document a Kappler fabric against a specific chemical hazard not already in our database, we make it easy with a custom testing program. We’ll conduct third-party testing on your chemical, and if the fabric meets your requirements you agree to purchase a standard minimum number of garments. For details contact Customer Service at 1-800-600-4019 or email us at customerservice@kappler.com.