Technical Data for Provent Products.

Physical Data: ProVent® 7000
Physical Property Test Method Results Imperial Results Metric
Basis Weight ASTM D751 1.78oz/yd2 60 g/m2
Grab Tensile Strength ASTM D751 MD 25 lbs CD 18 lbs MD 111 N CD 80 N
Trapezoid Tear ASTM D1117 MD 5.4 lbs CD 4.4 lbs MD 24 N CD 19.5 N
Ball Burst ASTM D751 23 lbs 103 N
Hydrostatic Resistance ASTM D751 PROCEDURE B, 1 127 cm+ 127 cm+
Moisture Vapor Transmission Rate ASTM E-96 PROCEDURE B 862 (g/m2/24hrs) 862 (g/m2/24hrs)
Surface Resistivity (ohm/cm) Anti-stat Properties ASTM D257 / NFPA 99 0.8x109 0.8x109
Bacterial Filtration Efficency Nelson Laboratories SOP / ARO / 007B >99.9% ≤ 3 microns >99.9% ≤ 3 microns
Synthetic Blood Penetration Resistance (Pass/Fail) ASTM F1670 PASS PASS
Physical Data: ProVent® 10,000
Physical Property Test Method Results Imperial Results Metric
Basis Weight ASTM D751 2.29oz/yd2 78 g/m2
Grab Tensile Strength ASTM D751 MD 51 lbs CD 36 lbs MD 226 N CD 160 N
Trapezoid Tear ASTM D5733 MD 5.3 lbs CD 11.2 lbs MD 23 N CD 49 N
Ball Burst ASTM D3787 46 lbs 204 N
Hydrostatic Resistance ASTM D751 PROCEDURE B, 1 127 cm+ 127 cm+
Moisture Vapor Transmission Rate ASTM E-96 PROCEDURE B 1035 (g/m2/24hrs) 1035 (g/m2/24hrs)
Surface Resistivity (ohm/cm) ASTM D257 / NFPA 99 4.7x108 4.7x108
Viral Penetration (Pass/Fail) ASTM F1671 PASS PASS
Synthetic Blood Penetration Resistance (Pass/Fail) ASTM F1670 PASS PASS
Physical Data: ProVent® 12,000
Physical Property Test Method Results Imperial Results Metric
Basis Weight ASTM D751 2.7 oz/yd2 91.5 g/m2
Grab Tensile Strength ASTM D751 MD 55 lbs CD 43 lbs MD 244 N CD 191 N
Trapezoidal Tear ASTM D1117 MD 19.4 lbs CD 10.7 lbs MD 86.2 N CD 47.5 N
Puncture Propagation Tear ASTM D2582 MD 8.93 lbs CD 12.42 lbs MD 39.7 N CD 55.2 N
Ball Burst ASTM D3787 53.1 lbs 236.1 N
Hydrostatic Resistance ASTM D751 PROCEDURE A 22 psi 151 kPa
Moisture Vapor Transmission Rate ASTM E-96 PROCEDURE D 1001 (g/m2/24hrs) 1001
Surface Resistivity (ohm/cm) ASTM D257 / NFPA 99 ≤1011 ≤1011
Synthetic Blood Penetration Resistance (Pass/Fail) ASTM F1670 PASS PASS
Viral Penetration (Pass/Fail) ASTM F1671 PASS PASS

Note: Sources for all test data generated are from independent laboratories. All tests were performed under laboratory conditions and not under actual use conditions. Tests were performed on material samples, not actual garments.

Warning: There are uses, environments and chemicals for which these garments and/or fabrics are unsuitable. It is the responsibility of the user to review available data and verify that the garment and/or fabric is appropriate for the intended use and meets all specified government and industry standards.

Caution: Do not use for fire protection. Avoid open flame or intense heat.