| Chemical | Zytron® 200 |
|---|---|
| Acetone | 17 |
| Acetonitrile | 52 |
| Carbon Disulfide | 2 |
| Dichloromethane | 2 |
| Diethylamine | 21 |
| Dimethylformamide | 77 |
| Ethyl Acetate | 14 |
| n-Hexane | 7 |
| Methyl Alcohol | >480 |
| Nitrobenzene | 97 |
| Sodium Hydroxide | >480 |
| Sulfuric Acid | >480 |
| Tetrachloroethylene | 21 |
| Tetrahydrofuran | 3 |
| Toluene | 6 |
| Gases | Zytron® 200 |
|---|---|
| Ammonia Gas | NT |
| 1,3 Butadiene | NT |
| Chlorine Gas | NT |
| Ethylene Oxide Gas | NT |
| Hydrogen Chloride Gas | NT |
| Methyl Chloride Gas | NT |
| Test Method | Zytron® 200 |
|---|---|
| Grab Tensile Strength MD* | 52 / 231 |
| Grab Tensile Strength CD* | 39 / 173 |
| Tear Resistance MD* | 22.9 / 101.8 |
| Trapezoid Method CD* | 9.6 / 42.7 |
| Ball Burst | 43 / 191 |
Note: Sources for all chemical test data are independent laboratories. All tests were performed under laboratory conditions and not under actual use conditions. Tests were performed on material samples, not actual garments. All chemicals tested at 95% and 75° F except Sodium Hydroxide, tested at 50%.
Note: These tests were performed in accordance with ASTM standards by independent laboratories. This data is derived from tests performed on material samples only, not finished garments.
Warning: There are uses, environments and chemicals for which these garments and/or fabrics are unsuitable. It is the responsibility of the user to review available data and verify that the garment and/or fabric is appropriate for the intended use and meets all specified government and/or industry standards.