Kappler Technical Data

ASTM F1001 Chemical Test Battery
Chemical Zytron® 100
Acetone NT
Acetonitrile NT
Carbon Disulfide NT
Dichloromethane NT
Diethylamine NT
Dimethylformamide NT
Ethyl Acetate NT
n-Hexane NT
Methyl Alcohol NT
Nitrobenzene NT
Sodium Hydroxide >480
Sulfuric Acid >480
Tetrachloroethylene NT
Tetrahydrofuran NT
Toluene NT
Gases Zytron® 100
Ammonia Gas NT
1,3 Butadiene NT
Chlorine Gas NT
Ethylene Oxide Gas NT
Hydrogen Chloride Gas NT
Methyl Chloride Gas NT
Typical Physical Properties (measured per ASTM D751)
Test Method Zytron® 100
Grab Tensile Strength MD* 32 / 142
Grab Tensile Strength CD* 24 / 106
Tear Resistance MD* 11.5 / 51
Trapezoid Method CD* 7.4 / 32
Ball Burst 28 / 124
*
MD -
Machine Direction
CD -
Cross Direction

Note: Sources for all chemical test data are independent laboratories. All tests were performed under laboratory conditions and not under actual use conditions. Tests were performed on material samples, not actual garments. All chemicals tested at 95% and 75° F except Sodium Hydroxide, tested at 50%.

Note: These tests were performed in accordance with ASTM standards by independent laboratories. This data is derived from tests performed on material samples only, not finished garments.

Warning: There are uses, environments and chemicals for which these garments and/or fabrics are unsuitable. It is the responsibility of the user to review available data and verify that the garment and/or fabric is appropriate for the intended use and meets all specified government and/or industry standards.