Physical Data ProVent 7,000

Physical Property Test Method Results Imperial Results Metric
Basis Weight ASTM D751 1.78oz/yd2 60 g/m2
Grab Tensile Strength ASTM D751 MD 25lbs CD 18lbs MD 111 N CD 80 N
Trapezoid Tear ASTM D1117 MD 5.4lbs CD 4.4lbs MD 24 N CD 19.5 N
Ball Burst ASTM D751 23lbs 103 N
Hydrostatic Resistance ASTM D751 PROCEDURE B, 1 127cm + 127cm +
Moisture Vapor Transmission Rate ASTM E-96 PROCEDURE B 862 (g/m2/24hrs) 862 (g/m2/24hrs)
Surface Resistivity (ohm/cm) Anti-stat Properties ASTM D257 / NFPA 99 0.8x109 0.8x109
Bacterial Filtration Efficency Nelson Laboratories SOP / ARO / 007B >99.9% ≤ 3 microns >99.9% ≤ 3 microns
Synthetic Blood Penetration Resistance (Pass/Fail) ASTM F1670 PASS PASS

Note: Sources for all test data generated are from independent laboratories. All tests were performed under laboratory conditions and not under actual use conditions. Tests were performed on material samples, not actual garments.

Warning: This information is based on technical data that Kappler believes to be reliable. It is subject to revision as additional knowledge and experience are gained. The website will contain Kappler’s most up-to-date product information, and customers who receive pamphlets, brochures or other literature should be aware that such “hard copy” information may not be as current as the information on Kappler’s website. Customers also should recognize that there are uses, environments and chemicals for which Kappler products, garments and/or fabrics are unsuitable. It is the responsibility of the user to review available data and verify that the product, garment and/or fabric is appropriate for the intended use and meets all specified government and/or industry standards. Also, the customer should review all available information on the website to understand the uses – and limitations – on ALL products, garments and fabrics which Kappler makes available.

Caution: Do not use for fire protection. Avoid open flame or intense heat.